Key Features
Only the wavelength that was selected can passed.
Applications
Automatic Optical Inspection Equipment(AOI Equipment)
Medical Equipments.
Sensors
Optical Equipments.
Laser Instruments.

Specifications
BP435
Spectral Characteristics |
|
| Tpeak=435 +/- 15nm |
| Tave<5% @ 200-375nm |
| Tave<5% @ 520-1050 |
| Physical Characteristics |
| Thickness |
| Glass: 3.3mm |
| Dimension |
| Square: 10*10 ~ 80*80mm |
| Round: 10 ~ 75mm |
| Resistant Temperature |
| 150 Celsius |
BP5055
Spectral Characteristics |
|
| Tave<5% @ 200-400nm |
| Tave>65% @ 520-530nm |
| Tave<5% @ 650-1050nm |
| Physical Characteristics |
| Thickness |
| Glass: 3.3mm |
| Dimension |
| Square: 10*10 ~ 50*50mm |
| Round: 10 ~ 45mm |
| Resistant Temperature |
| 150 Celsius |
BP510 (485/535)
Spectral Characteristics |
|
| Tave<5% @ 200-420nm |
| Tave>70% @ 505-515nm |
| Tave<5% @ 580-1000nm |
| Physical Characteristics |
| Thickness |
| Glass: 1.1mm |
| Dimension |
| Square: 8*8 ~ 160*160mm |
| Round: 8 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP560 (530/585)
Spectral Characteristics |
|
| Tave<5% @ 200-480nm |
| Tave>70% @ 550-570nm |
| Tave<5% @ 630-1000nm |
| Physical Characteristics |
| Thickness |
| Glass: 1.1mm |
| Dimension |
| Square: 8*8 ~ 160*160mm |
| Round: 8 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP5060
Spectral Characteristics |
|
| Tave<5% @ 430-470nmnm |
| Tave>85% @ 530-570nm |
| Tave<5% @ 680-1050nm |
| Physical Characteristics |
| Thickness |
| Glass: 1.1mm |
| Dimension |
| Square: 8*8 ~ 160*160mm |
| Round: 8 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP630
Spectral Characteristics |
|
| Tave<5% @ 200-480nm |
| T PEAK=630 +/- 15nm |
| Tave<5% @ 720-11050nm |
| Physical Characteristics |
| Thickness |
| Glass: 2.2mm |
| Dimension |
| Square: 10*10 ~ 160*160mm |
| Round: 10 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP6570
Spectral Characteristics |
|
| Tave<5% @ 200~570nm |
| Tave>70% @ 665-690nm |
| Tave<5% @ 780-1050nm |
| Physical Characteristics |
| Thickness |
| Glass: 2.2mm |
| Dimension |
| Square: 10*10 ~ 160*160mm |
| Round: 10 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP6070
Spectral Characteristics |
|
| Tave<5% @ 420-560nm |
| Tave>80% @ 640-660nm |
| Tave<5% @ 750-1100nm |
| Physical Characteristics |
| Thickness |
| Glass: 0.7, 1.1mm |
| Dimension |
| Square: 10*10 ~ 160*160mm |
| Round: 10 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP8090
Spectral Characteristics |
|
| Tave<5% @ 420-650nm |
| Tave>75% @ 840-860nm |
| Tave<5% @ 950-1100nm |
| Physical Characteristics |
| Thickness |
| Glass: 0.55, 0.7, 1.1mm |
| Dimension |
| Square: 10*10 ~ 160*160mm |
| Round: 10 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
BP8493
Spectral Characteristics |
|
| Tave<5% @ 420-780nm |
| Tave>85% @ 840-904nm |
| Tave<5% @ 1000-1100nm |
| Physical Characteristics |
| Thickness |
| Glass: 0.7, 1.1mm |
| D263T(*7): 0.3, 0.55, 0.7mm |
| Dimension |
| Square: 10*10 ~ 160*160mm |
| Round: 10 ~ 150mm |
| Resistant Temperature |
| 150 Celsius |
| D263T: 300 Celsius |
BP8998
Spectral Characteristics |
|
| Tave<5% @ 420-850nm |
| Tave>85% @ 930-950nm |
| Tave<5% @ 1000-1100nm |
| Physical Characteristics |
| Thickness |
| Glass: 0.7, 1.1mm |
| D263T(*7): 0.3, 0.55, 0.7mm |
| Dimension |
| Square: 4*4 ~ 160*160mm |
| Round: 4 ~ 150mm |
| Resistant Temperature |
| Glass: 150 Celsius |
| D263T: 300 Celsius |
Narrow Bandpass Filters
Demension: Diameter 12, 12.7, 15, 25, 25.4mm
Center Wavelength(nm) |
Bandwidth(nm) |
Peak Transmittance(nm) |
340 |
11 |
40 |
405 |
10 |
35 |
450 |
10 |
50 |
505 |
10 |
50 |
600 |
10 |
50 |
650 |
11 |
50 |
706 |
11 |
50 |
750 |
11 |
45 |
850 |
12 |
45 |
940 |
13 |
45 |
1064 |
10 |
45 |
Information and Notes
1. Bandpass filters with 34~62 thin film layers which vacuum-deposited on substrate.
2. Coating by PVD-EBGE (Physical Vapor Deposition-Electron Beam Gun Evaporation).
3. Some Bandpass filter combo with multi filters, and thickness range may from 1.1 ~ 4.4mm.
4. Bandpass filters also offer standard camera ring ex: M49, M52, M55, M58.
5. The transmittance curves are measurements at 0° of incidence angle.
6. The transmittance curves are based on actual measurements and may be different with manufacturing lots.
7. D263T is registered trademarks of SCHOTT AG.
|